| Error code | Possible fault |
|---|---|
| E09 | Gas valve connection fault. |
| E10 | External probe fault. |
| E12 | Differential water flow switch fault (still open). |
| E13 | Differential water flow switch fault (still closed). |
| E15 | Gas valve command fault. |
| E20 | Central heating NTC sensor fault - short circuit/open circuit. |
| E28 | Flue NTC sensor fault- short circuit/open circuit. |
| E40 | Return central heating NTC sensor fault- short circuit/open circuit. |
| E50 | DHW NTC sensor fault (tank boiler) - short circuit/open circuit. |
| E83 / E84 / E85 / E86 / E87 | No communication. |
| E103 | Safety Assist battery is exhausted. |
| E104 | Faulty Safety Assist PCB. |
| E107 | PCBs not synchronised. |
| E109 | Precirculation alarm. |
| E110 | (i) Boiler max. temperature exceeded for gradient (probable pump jammed or air in the circuit). (ii) Safety thermostat sensor tripped. |
| E118 | Water pressure LOW (<0.5 bar). |
| E125 | Water circulation fault. |
| E128 | Safety error for frequent loss of flame. |
| E129 | Safety error for frequent loss of flame with max correction during ignition during Calibration Function. |
| E130 | Flue thermostat sensor tripped (lockout). |
| E133 | Gas supply fault. Check the power supply, sensing electrode, spark electrode and cable. |
| E134 | Elapsed time gas valve open without gas (short request in a short period). |
| E135 | Internal error. |
| E154 | Plausibility test (flow/return). |
| E160 | Fan fault. |
| E270 | Dry fire. |
| E317 / 162 | Wrong power supply electrical frequency (Hz). |
| E321 / 163 | Domestic Hot Water NTC sensor fault (s.c.). |
| E321 / 163 | Domestic Hot Water NTC sensor fault (o.c.). |
| E384 / 164 | False flame (parasitic flame). |
| E385 / 165 | Under voltage. |
| E430 / 166 | Water pressure temporary fault. |
| E430 / 166 + Flame 'crossed' | Water pressure test failed. |