Baxi HP60 High Temperature Monobloc Air Source Heat Pump

Heat Pumps

Baxi HP60 High Temperature Monobloc Air Source Heat Pump

The Baxi HP60 ASHP delivers reliable performance and quiet operation using a low GWP 3 refrigerant, helping you meet today’s expectations and tomorrows regulations.

 

Available in a wide range of outputs the Baxi HP60 ASHP is a self-contained outdoor air source heat pump that delivers outstanding energy performance at both high and medium temperature. For a complete system and maximum efficiency, pair it with our Baxi ASHP Pre-plumbed Cylinder or Baxi ASHP Cylinder and smart controls.

 

Extremely quiet with excellent SCOP ratings, it is the perfect solution for retrofit applications.

Air Source Heat Pump heating system - Baxi Ireland

ASHP solutions built around you, backed by us

Our comprehensive range of Air Source Heat Pump solutions fits the needs of every project – and with expert support always on hand, you can trust us to deliver. When it comes to ASHPs, we’ve got the lot.

Features and Benefits

Multiple outputs

Available in outputs 4kW – 13kW all single phase with optional triple phase for large outputs

    High temperature

    Up to 75°C flow temperature at A-10°C

      Quiet operation

      Sound power from 48 dB(A), which is the equivalent of a refrigerator hum

        High efficiency

        Seasonal Coefficient of Performance (SCOP) of up to 5.34

          Built for lower impact

          Low carbon emissions of GWP 3

            Compatible

            Compatible with Baxi ASHP Pre-plumbed Cylinder and Baxi ASHP Cylinder

              Warranty

              Up to 7 years’ enhanced warranty*
                Show More
                Show Less

                Product Literature

                Installation and Service Manuals

                Installation and Service Manuals

                Product Documentation

                No documentation available.

                User Guides

                User Guides

                Product Documentation

                No documentation available.

                Technical Specifications

                Technical Specifications

                Product Documentation

                No documentation available.

                Energy Labels

                Energy Labels

                Product Documentation

                No documentation available.

                Product Fiche

                Product Fiche

                Product Documentation

                No documentation available.

                Download the Baxi Residential Solutions guide

                From boilers and cylinders to ASHPs and accessories, our Baxi Residential Solutions Guide gives you everything you need to deliver complete, reliable heating and hot water solution. Download it today to explore our full product portfolio.

                Baxi HP60 High Temperature Monobloc Air Source Heat Pump - 4-6kW models - Dimensions

                Dimensions

                4-6kW models

                A: Heat Pump Width = 1301mm

                B: Heat Pump Height = 725mm

                C: Heat Pump Depth = 426mm

                D: Unit Volume = 0.36 m3

                Baxi HP60 High Temperature Monobloc Air Source Heat Pump - 8-11-1kW models - Dimensions

                Dimensions

                8-11-13kW models

                A: Heat Pump Width = 872mm

                B: Heat Pump Height = 523mm

                C: Heat Pump Depth = 1390mm

                D: Unit Volume = 0.59 m3

                Technical Specification

                Product Model4 kW6 kW8 kW11kW11 kWφ13 kW13 kWφ
                Product Code7899701789970278997037899704789970578997067899707
                Product Information
                Min/Max Operating Range (℃)-25/+35-25/+35-25/+35-25/+35-25/+35-25/+35-25/+35
                SCOP 35°C5.345.225.204.774.774.704.70
                35°C Maximum Output (1)
                A-5°C W+35°C 5.91 kW6.63 kW9.72 kW11.82 kW11.82 kW14.83 kW14.83 kW
                A0°C W+35°C6.28 kW7.22 kW10.33 kW13.14 kW13.14 kW16.13 kW16.13 kW
                A+7°C W+35°C6.86 kW7.70 kW11.05 kW14.72 kW14.72 kW17.57 kW17.57 kW
                35°C Nominal Output (2)
                A-5°C W+35°C 4.12 kW5.98 kW8.10 kW10.37 kW10.37 kW11.94 kW11.94 kW
                A0°C W+35°C4.29 kW5.91 kW8.15 kW10.97 kW10.97 kW12.54 kW12.54kW
                A+7°C W+35°C4.40 kW6.26 kW8.50 kW11.50 kW11.50 kW13.50 kW13.50 kW
                SCOP 45°C4.404.354.344.094.094.064.06
                45°C Maximum Output (1)
                A-5°C W+45°C 5.65 kW6.33 kW9.49 kW11.32 kW11.32 kW14.22 kW14.22 kW
                A0°C W+45°C5.99 kW6.88 kW10.02 kW12.58 kW12.58 kW15.49 kW15.49 kW
                A+7°C W+45°C6.55 kW7.35 kW10.47 kW14.06 kW14.06 kW16.85 kW16.85 kW
                45°C Nominal Output (2)
                A-5°C W+45°C 3.97 kW5.71 kW8.0 kW10.40 kW10.40 kW12.89 kW12.89 kW
                A0°C W+45°C4.35 kW6.03 kW8.07 kW11.00 kW11.00 kW12.91 kW 12.91 kW
                A+7°C W+45°C4.40 kW6.30 kW8.23 kW11.50 kW11.50 kW13.50 kW13.50 kW
                SCOP 55°C3.993.903.893.753.753.733.73
                55°C Maximum Output (1)
                A-5°C W+55°C 5.15 kW5.79 kW8.40 kW11.02 kW11.02 kW12.95 kW12.95 kW
                A0°C W+55°C5.68 kW6.57 kW9.16 kW12.14 kW12.14 kW14.64 kW14.64 kW
                A+7°C W+55°C6.20 kW6.97 kW10.17 kW13.61 kW13.61 kW16.40 kW16.40 kW
                55°C Nominal Output (2)
                A-5°C W+55°C 4.28 kW5.44 kW7.29 kW10.30 kW10.30 kW11.50 kW11.50 kW
                A0°C W+55°C4.40 kW5.50 kW7.52 kW10.80 kW10.80 kW12.78 kW12.78 kW
                A+7°C W+55°C4.40 kW6.10 kW8.00 kW11.50 kW11.50 kW13.50 kW13.50 kW
                Sound Pressure Level @1m40.0 dB(A)40.0 dB(A)41 dB(A)44.0 d(B)A44.0 d(B)A44.0 d(B)A44.0 dB(A)
                Sound Power Level (ERP)48.0 dB(A)48.0 dB(A)49 d(B)A52.0 d(B)A52.0 d(B)A52.0 d(B)A 52.0 dB(A)
                ERP @ 35℃A+++A+++A+++A+++A+++A+++A+++
                ERP @ 55℃A+++A+++A+++A++A++A++A++
                Power Supply (V/Ph/Hz)220V-240V/1Ph/50Hz220V-240V/1Ph/50Hz220V-240V/1Ph/50Hz220V-240V/1Ph/50Hz380V-415V/3Ph/50Hz220V-240V/1Ph/50Hz380V-415V/3Ph/50Hz
                MCA (A)12 A13.5 A17.5 A25 A8.5 A28 A9.5 A
                TOCA (A)15 A 15 A19 A31 A11 A31 A11 A
                MFA (A)16 A16 A20 A32 A16 A32 A16 A
                Flow/Return ConnectionsG 1G 1G 1 1/4G 1 1/4G 1 1/4G 1 1/4G 1 1/4
                Internal Expansion Vessel8 L8 L8 L8 L8 L8 L8 L
                Pre-Pressure1.5 Bar1.5 Bar1.5 Bar1.5 Bar1.5 Bar1.5 Bar1.5 Bar
                Maximum Water Pressure3 Bar3 Bar3 Bar3 Bar3 Bar3 Bar3 Bar
                Minimum System Volume at 55°C26 L26 L42 L49 L49 L51 L51 L
                RefrigerantR290R290R290R290R290R290R290
                Refrigerant Volume0.7 kg0.7 kg1.1 kg1.25 kg1.251.25 kg1.25 kg
                Compressor TypeTwin rotary / GMCCTwin rotary / GMCCTwin rotary / GMCCTwin rotary / GMCCTwin rotary / GMCCTwin rotary / GMCCTwin rotary / GMCC
                Volumetrics
                Weight Net94 kg94 kg122 kg140 kg142 kg140 kg142 kg
                Weight with Packaging114 kg114 kg144 kg162 kg164 kg162 kg164 kg

                (1) Output values tested at maximum compressor frequency

                (2) Nominal values under test conditions EN14825:2013

                Selections and sizing offered by Baxi utilise nominal values unless otherwise stated

                Contact your ASM

                If you are a merchant or installer, your local Baxi representative is here to help.

                More Information

                Baxi Works App

                Baxi Works

                A simpler and more rewarding experience for installers, all in one place.

                The Whys, Hows and Whats of Heat Loss Calculations - Baxi

                The Whys, Hows and Whats of Heat Loss Calculations

                As heating installers, understanding how to calculate heat loss is a crucial part of designing and installing efficient heating systems, especially given the rise of boiler alternatives.

                † Terms and conditions apply.